At home: "The power was out about 9 hours this year" sounds bad. "99.9% uptime" sounds great. They're the same thing.

In the system: Availability is the fraction of time (or of requests) a service works. Each extra nine cuts allowed downtime by 10×:

a table of nines; availabilities multiply in a chain, failures multiply in parallel.

Figure: every extra nine costs much more; chains lose nines, parallel copies gain them.

AvailabilityDown per 30-day monthDown per year
99%7.2 hours3.65 days
99.9%43 minutes8.8 hours
99.99%4.3 minutes53 minutes
99.999%26 seconds5.3 minutes

Two rules:

  • In series (all parts needed), availabilities multiply: checkout needs payment (99.9%), inventory (99.9%) and itself (99.95%): about 99.75%, lower than any single part.
  • In parallel (any one is enough), failure probabilities multiply: two independent copies at 99% each give 1 − 0.01 × 0.01 = 99.99%.

So: keep the critical path short, make non-essential calls optional (a down recommendations service shouldn't count against checkout), and add redundancy where it buys real nines. Chapter 30 turns these numbers into targets (SLOs) and error budgets.

Memory code: "Each nine is ten times less downtime; chains lose nines, copies gain them."